Yamatake st3000 manual




















Please have your complete model number, serial number, and software revision number on hand for reference. You can find the model and serial numbers on the transmitter nameplates. Honeywell Solution Support Center e-mail: ace honeywell. Depending on your transmitter options, the transmitter may be equipped with either a 3-screw or 5-screw terminal block inside the electronics housing.

This may affect how to connect the loop wiring and meter wiring to the transmitter. See Section 4. Section 5 provides additional wiring diagrams showing alternate wiring methods. Before you dispose of the shipping container, be sure you have removed all the contents and visually inspected the transmitter for signs of shipping damage. Report any such damage to the carrier. Each series includes several models to meet various process pressure measurement and interface requirements.

The model number format consists of a Key Number with several Table selections as shown below. You can quickly identify what series and basic type of transmitter you have from the third and fourth digits in the key number. The letter in the third digit represents one of these basic transmitter types:. The number in the fourth digit matches the first digit in the transmitter Series. For a complete breakdown of the table selections in your model number, please refer to the appropriate Specification and Model Selection Guide that is provided as a separate document.

Previous models of the ST transmitter with designations of Series , Series e, Series , and Series have been supplied at various times since the ST was introduced in While all these transmitters are functionally alike, there are differences in housing and electronics design. This Installation Guide only applies for Release , Series transmitters with software version 3. Communication with your ST Smart Transmitter can be accomplished by using any of the following interfaces:.

The SFC will operate with transmitters that have older software versions, but functions will be limited to those applicable for the transmitter software. It is a bundled Microsoft Windows software and PC-interface hardware solution that allows quick, error-free configuration of Honeywell Smartline field instruments. Please contact your Honeywell representative for more information. The bench check is an optional procedure for checking your transmitter before you install it by:.

See the Configuration section in the ST Smart. Use the procedure in Table 3 to display all the basic transmitter database parameters to be sure they are correct. Transmitters are shipped with a default failsafe direction of upscale. You can change the direction from upscale to downscale minimum output by cutting jumper W1 on the printed wiring assembly PWA.

The STDC card initiates the failsafe mode configured through the transmitter when either signal is generated. The failsafe direction display that you can access through the SFC only shows the state of the failsafe jumper in the transmitter as it correlates to analog transmitter operation. The failsafe action of the digital control system may be configured to operate differently than indicated by the state of the jumper in the transmitter.

Follow these tips to minimize chances of static electricity damage when handling the PWA. If you must touch the PWA circuits, be sure you are grounded by staying in contact with a grounded surface or wearing a grounded wrist strap.

There is no need to check the jumper position unless you want to change it. Refer to the steps in Table 4 to remove the PWA from the transmitter and Figure 3 to reposition the jumper. Refer to the procedure for setting the range values to applied pressures using local zero and span adjustments in Appendix A Smart Meter Reference in this guide.

Evaluate conditions The ST transmitter is designed to operate in common indoor industrial environments as well as outdoors.

To assure optimum performance, evaluate these conditions at the mounting area relative to published transmitter specifications and accepted installation practices for electronic pressure transmitters.

Figure 4 illustrates typical mounting area considerations to make before installing a transmitter. For more specific information, refer to the appropriate Specification and Model Selection Guide or transmitter nameplate.

Note: To convert bar values to kilopascals kPa , multiply by For example, 3. Use metric hex wrench 2. Always recharge the SFC battery pack in a nonhazardous location.

The SFC itself is an intrinsically safe device. Also, be sure any switches that may trip alarms or interlocks associated with the analog loop are secured or turned OFF. Communication superimposes digital signals on the loop wiring that could affect the analog control signal.

The Smartline Configuration Toolkit SCT consists of the software program which is contained on diskettes and a Smartline Option Module which is the hardware interface used for connecting the host computer to the ST transmitter. Be certain that the host computer is loaded with the proper operating system necessary to run the SCT program. If your ST transmitter is equipped with a Local Smart Meter option, you may want refer to the design and operating specifications for this option.

Secure with nuts and lockwashers provided. NOTE: If the meter body is hexagonal, you must use the additional bracket supplied. If meter body is round, discard the bracket. Rotate Transmitter housing in maximum of degree increment in left or right direction from center to position you require and tighten set screw 1.

You will need the 4mm size wrench for the outside set screw. To minimize these positional effects on calibration zero shift , take the appropriate mounting precautions that follow for the given transmitter model. You do this by leveling the transmitter side-to-side and front-to-back. See Figure 6 for suggestions on how to level the transmitter using a spirit balance.

For a transmitter with a small differential pressure span, you must ensure that the transmitter is vertical when mounting it. You must also zero the transmitter by following the steps in Table 9 below. Welcome to ManualMachine. We have sent a verification link to to complete your registration. Log In Sign Up. Forgot password? Enter your email address and check your inbox.

Please check your email for further instructions. Enter a new password. ST Printed in U. February While this information is presented in good faith and believed to be accurate, Honeywell disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.

Windows, Windows 95 are trademarks of Microsoft Corporation. Information Mapping is a trademark of Information Mapping Inc. Union Hills Drive Phoenix, Arizona Patent Notice This product is covered by one or more of the following U. Observe precautions for handling electrostatic sensitive devices Protective Earth PE terminal.

Acronyms AP Absolute Pressure APM American Wire Gauge DE Differential Pressure EMI Electromagnetic Interference GP Gauge Pressure HP High Pressure HP Inches of Water KCM Low Pressure LP Lower Range Value mA Milliamperes mmHg Millimeters of Mercury NPT Printed Circuit Board PM Upper Range Value Vdc Technical Assistance If you encounter a problem with your ST Smart Transmitter, check to see how your transmitter is currently configured to verify that all selections are consistent with your application.

By E-mail You can also e-mail your technical questions or comments about this product to: Honeywell Solution Support Center e-mail: ace honeywell. Transmitter Terminal Blocks. Section 1 —Getting Started 1. Operation of this equipment in a residential area may cause harmful interference. This equipment generates, uses, and can radiate radio frequency energy and may cause interference to radio and television reception when the equipment is used closer than 30 meters 98 feet to the antenna e.

In special cases, when highly susceptible apparatus is used in close proximity, the user may have to employ additional mitigating measures to further reduce the electromagnetic emissions of this equipment. Checking ST shipment Series and model number data. Contact us if there is a problem with the order or an item is missing. Continued on next page. Communicating with the ST Transmitter, continued.

It also includes the same installation data contained in this installation guide to minimize cross reference. But, the optional bench check function and reference dimension drawings list are included in this guide only. Appendix A Smart Meter Reference contains configuration and operating information for using the the ST when it is equipped with the smart meter option option SM.

Section 2 —Optional Bench Check 2. Also, if your transmitter was not configured at the factory, you can do so during this procedure. About the azbil Group. Market-specific Solutions. Support and Training. Solutions for Factory and Plant Problems. Case Studies. Investor Relations. Building automation BA systems, security systems, services, and solutions for buildings.

A variety of advanced products, services, solutions, etc. In the virtual tour, visitors can also connect to the Fujisawa Technology Center virtual tour and view an introductory video of Solution and Technology Center in Thailand. Expand your knowledge on trending industry topics with Azbil's high quality whitepapers and articles.

Download all our white papers and articles for free now! Serving Customers Worldwide. Home Products Electrical Hydraulic Mechanical. Forgot Password?



0コメント